EB200 Manual
.
.
[CW|FIXed]? [MINimum|MAXimum]
Query of receiver frequency
Parameters:
none
MINimum|MAXimum
Result:
Frequency value in Hz
Example:
FREQuency? -> 98500000
.
.
:DSCan
If the STARt and/or STOP frequency is changed then CENTer or SPAN is adjusted.
If CENTer of SPAN is changed, then the STARt or STOP frequency is adjusted.
Either CENTer and SPAN or STARt and STOP frequency can be changed in a command at the same
time. Other parameter combinations will be rejected.
.
.
.
:CENTer <numeric_value>|MINimum|MAXimum
Sets the center frequency of Digiscan.
Corrects STARt and STOP frequency.
Parameter:
<numeric-value>
MINimum | MAXimum
*RST state:
97.5 MHz
Example:
FREQuency : DSCan : CENTer
.
.
.
:CENTer? [MINimum|MAXimum]
Query of the center frequency of Digiscan
Parameters:
none
MINimum | MAXimum
Result:
Frequency value in Hz
Example:
FREQuency : DSCan : CENTer? → 118000000
4052.2000.02
query of current receiver frequency
query of lowest|highest receiver frequency
frequency value
setting min/max center frequency
118 MHz
query of the current center frequency
query of the min/max center frequency