EB200 Manual
.
:CONTents? <name>|RX
Query of contents of memory location
Parameters:
<name>
Result:
Depending on the setting by the command FORMat:MEMory either an ASCII data set or a binary data
set is output:
The ASCII data set has the following structure:
<F>,<THR>,<DEM>,<BW>,<ANT>,<ATT>,<ATTA>,<SQUC>,<AFC>,<ACT>
<F>
<THR>
<DEM>
<BW>
<ANT>
<ATT>
<ATTA>
<SQUC>
<AFC>
<ACT>
The binary data set is transferred as a <Definite Length Block> and has to be interpreted
according to the above-mentioned format.
Notes:
•
During query of the receiver data set (RX) the parameter <ACT> is not defined and has to be
ignored.
•
When trying to read out an empty memory location the error message "MEMORY EMPTY" is
generated.
Example:
MEMory:CONTents? MEM1 ->
.
.
:MPAR <name>,<ACT>
Setting the memory location parameter (MPAR = MemoryPARameter) <ACT>
Parameters:
<name>
<ACT>
Example:
MEMory:CONTents:MPAR MEM1, OFF
4052.2000.02
MEM0 to MEM999 | RX | CURRENT
frequency (see SENS:FREQ:CW?)
squelch threshold (see OUTP:SQU:THR?)
demodulation type (see SENS:DEM?)
bandwidth (see SENS:BWID?)
antenna number (see ROUT:CLOS:STAT?)
attenuator (see INP:ATT:STAT?)
attenuator auto (see INP:ATT:AUTO?)
squelch function (see OUTP:SQU:STAT?)
AFC function (see (SENS:FREQ:CW:AFC?)
set/reset for scan (1/0)
98500000,34,FM,100000,#14(@1),0,1,1,0,1
MEM0 to MEM999 | CURRENT
setting/resetting the memory to the scan (ON/OFF or 1/0)
4.44
MEMory subsystem
E-7
Need help?
Do you have a question about the EB200 and is the answer not in the manual?
Questions and answers