3.18.1.1 M-SCAN - CONFIG

This menu is obtained by pressing the CONF softkey in the M-SCAN menu.
Softkeys
RUN-:
Scan starts from current memory location number, decreasing frequency, menu change
after M-SCAN
RUN+:
Scan starts from the current memory location number, increasing frequency, menu
change after M-SCAN
ACTIVATE:
Memory location with the number MEM-NO set for scanning
SUPP:
Memory location with number MEM-NO is suppressed
DELETE:
Branching to temporary pop-up menu with repeated scan (see "M-SCAN - CONFIG -
DELETE" on page 28)
RX <->MEM:
The receiver parameter values are swapped with the values in the memory location
Note:
Memory location contents can be edited best with the control elements of the receiver. In order to
transmit the data from the memory location to the receiver and vice versa, beside the softkey RX<-
>MEM, the hardkeys SAVE and RCL are also available. See also memory function on page 18.
Memory location contents
FRQ
Receive frequency
MOD
Demodulation mode
BW
Bandwidth
SQ
Squelch OFF or squelch value
ANT
Antenna number (controlled by CPU in stationary mode)
ATT
Attenuation
AFC
Automatic frequency control (only relevant for listen mode)
The following parameters are global and are not stored at any memory location:
LEV
Level indicator (not relevant when M-SCAN is running)
MGC/AGC
Gain control (depends on the current reception conditions)