4.5.9 INPut subsystem

INPut
.
:ATTenuation
.
.
:AUTO <Boolean>
Setting attenuation so that the best dynamic range is obtained; explicit switch on/off of attenuator sets
AUTO to OFF
Parameters:
ON
OFF
*RST state:
ON
Example:
INPut:ATTenuation:AUTO ON
.
.
:AUTO?
Query of the automatically attenuation setting
Parameters:
none
Result:
Attenuation is automatically switched 1
Attenuation is manually switched 0
Example:
INPut:ATTenuation:AUTO? -> 1
.
.
:STATe <Boolean>
Switch on/off of input attenuator
Parameters:
ON
OFF
*RST state:
level-dependent (because of INPut:ATTenuation:AUTO ON after *RST)
Example:
INPut:ATTenuation:STATe ON
4052.2000.02
attenuation is coupled to input-signal strength
attenuation is manually switched
attenuator on
attenuator off