:VOLTage:AC:RANGe
.
.
[:UPPer]<numeric_value>UP|DOWN|MINimum|MAXimum
This command is used in the DSCAN mode to set the reference level. In order to avoid overdriving of
the receiver, the reference level is set to the highest expected positive signal level.
Parameters:
<numeric_value>
UP|DOWN
MINimum|MAXimum
*RST state:
70 dB µ V
Example:
VOLTage:AC:RANGe 90 dBµV
.
.
.
:RANGe? [MINimum|MAXimum]
Query of reference level
Parameters:
none
MINimum|MAXimum
Result:
Reference level in dBµV.
Example:
VOLTage:AC:RANGe? -> 90
.
.
.
.
:STEP
.
.
.
.
.
Setting the stepwidth for the command VOLTage:AC:RANGe UP|DOWN
Parameters:
<numeric_value>
MINimum|MAXimum
*RST state:
1 dBuV
Example:
VOLTage:AC:RANGe:STEP 10 dBuV
4052.2000.02
reference level in dBµV
|increase | decrease of the reference level by the value that was
set by command VOLTage:AC:RANGe:STEP[:INCRement]
minimum|maximum reference level
query of current reference level
query of lowest|highest reference level
[:INCRement] <numeric_value>|MINimum|MAXimum
stepwidth of reference level in dBuV
setting the minimum|maximum stepwidth
SENSe subsystem VOLTage