EB200 Manual
.
.
:COUNt? [MINimum|MAXimum]
Query of number of sweeps
Parameters:
none
MINimum|MAXimum
Result:
Number of sweeps; 9.9E37 is output for an infinite number
Example:
SWEep:COUNt? -> 100
.
.
:DIRection UP|DOWN
Setting the scan direction
Parameters:
UP
DOWN
*RST state:
UP
Example:
SWEep:DIRection DOWN
.
.
:DIRection?
Query of scan direction
Parameters:
none
Result:
UP, DOWN
Example:
SWEep:DIRection? -> DOWN
4052.2000.02
query of current number of sweeps
query of minimum|maximum sweeps
scan with increasing frequency
scan with decreasing frequency
4.90
SENSe subsystem SWEep