4 Start-Up Programming & Operation
T2-08: Number of PM Motor Poles
Enter the number of motor poles.
No.
T2-08
<1> When PG-E3 option connected: Max setting = 48
T2-09: PM Motor Base Speed
Enter the motor rated speed in r/min.
Note: T2-09 will be displayed when in CLV/PM.
No.
T2-09
T2-10: PM Motor Stator Resistance
Enter the motor stator resistance per motor phase.
No.
T2-10
T2-11: PM Motor d-Axis Inductance
Enter the d axis inductance per motor phase.
No.
T2-11
T2-12: PM Motor q-Axis Inductance
Enter the q axis inductance per motor phase.
No.
T2-12
T2-13: Induced Voltage Constant Unit Selection
Selects the units used for setting the induced voltage coefficient.
No.
T2-13
Setting 0: mV (r/min)
Setting 1: mV (rad/sec)
Note: If T2-13 is set to 0, then the drive will use E5-24 (Motor Induction Voltage Constant 2), and will automatically set E5-09 (Motor
Induction Voltage Constant 1) to 0.0. If T2-13 is set to 1, then the drive will use E5-09 and will automatically set E5-24 to 0.0.
T2-14: PM Motor Induced Voltage Constant
Enter the motor induced voltage constant.
No.
T2-14
80
Parameter Name
Number of PM Motor Poles
Parameter Name
PM Motor Base Speed
Parameter Name
PM Motor Stator Resistance
Parameter Name
PM Motor d-Axis Inductance
Parameter Name
PM Motor q-Axis Inductance
Parameter Name
Induced Voltage Constant Unit Selection
Parameter Name
PM Motor Induced Voltage Constant
YASKAWA ELECTRIC TOEP C710616 38H YASKAWA AC Drive-L1000A Quick Start Guide
Setting Range
2 to 120
<1>
Setting Range
0 to 24000 r/min
Setting Range
0.000 to 65.000 Ω
Setting Range
0.00 to 600.00 mH
Setting Range
0.00 to 600.00 mH
Setting Range
0, 1
Setting Range
0.0 to 2000.0
Depending on T2-02
Default
6
Default
150 r/min
Default
Default
Default
Default
1
Default