B Parameter Table
H1-
Function
Setting
1A
Accel/decel Ramp Selection 2
20 to 2F
External Fault
50
Nominal Speed
51
Intermediate Speed
52
Releveling Speed
53
Leveling Speed
54
Inspection Operation
55
Rescue Operation
56
Motor Contactor Feedback
57
High Speed Limit (Up)
58
High Speed Limit (Down)
5A
Motor Contactor Feedback 2
<44>
5B
Brake Feedback 2
<44>
5C
Floor Sensor
67
Communications Test Mode
79
Brake Feedback
<44> Available in drive software versions PRG: 7017 or later.
184
H1 Multi-Function Digital Input Settings
Used in conjunction with an input terminal set for "Accel/decel ramp selection 1" (H1- = 7), and
allows the drive to switch between accel/decel ramp 3 and 4.
20: N.O., Always detected, ramp to stop
21: N.C., Always detected, ramp to stop
22: N.O., During run, ramp to stop
23: N.C., During run, ramp to stop
24: N.O., Always detected, coast to stop
25: N.C., Always detected, coast to stop
26: N.O., During run, coast to stop
27: N.C., During run, coast to stop
28: N.O., Always detected, Fast Stop
29: N.C., Always detected, Fast Stop
2A: N.O., During run, Fast Stop
2B: N.C., During run, Fast Stop
2C: N.O., Always detected, alarm only (continue running)
2D: N.C., Always detected, alarm only (continue running)
2E: N.O., During run, alarm only (continue running)
2F: N.C., During run, alarm only (continue running)
Closed: Activates the nominal speed (d1-19).
Closed: Activates the Intermediate Speed (d1-20).
Closed: Activates the Releveling Speed (d1-23).
Closed: Activates the Leveling Speed (d1-26).
Closed: Activates Inspection operation using the speed set in d1-24.
Closed: Activates rescue operation.
Open: Motor contactor open
Closed: Motor contactor closed (N.O.)
Closed: Uses the leveling speed as the maximum speed when going up.
Closed: Uses the leveling speed as the maximum speed when going down.
Open: Motor contactor closed (N.C.)
Closed: Motor contactor open
Open: Brake open (N.C.)
Closed: Brake closed
Closed: Initiate Direct Landing (S5-10 = 1)
Tests the MEMOBUS/Modbus RS-485/422 interface. Displays "PASS" if the test completes
successfully.
Open: Brake closed
Closed: Brake open (N.O.)