H2: Multi-Function Digital Outputs
No.
Name
Terminals M1-M2
H2-01
Function Selection (relay)
Terminals M3-M4
H2-02
Function Selection (relay)
Terminals M5-M6
H2-03
Function Selection (relay)
Terminal P1-C1 Function
H2-04
Selection (photocoupler)
Terminal P2-C2 Function
H2-05
Selection (photocoupler)
H2-
Function
Setting
0
During Run
1
Zero Speed
2
Speed Agree 1
3
User-set Speed Agree 1
4
Speed Detection 1
5
Speed Detection 2
6
Drive Ready (READY)
7
DC Bus Undervoltage
8
During Baseblock (N.O.)
9
Speed Reference Source
A
Up/Down Command Source
B
Torque Detection 1
E
Fault
F
Not used (Through Mode)
10
Minor Fault
Fault Reset Command
11
Active
12
Timer Output
13
Speed Agree 2
14
User-set Speed Agree 2
15
Speed Detection 3
16
Speed Detection 4
18
Torque Detection 2
1A
During Down Direction
1B
During Baseblock 2 (N.C.)
YASKAWA ELECTRIC TOEP C710616 38H YASKAWA AC Drive-L1000A Quick Start Guide
Refer to
H2 Multi-Function Digital Output Settings on page 185
setting values.
H2 Multi-Function Digital Output Settings
Closed: An Up/Down command is active or voltage is output.
Open: Output speed is greater than the value of E1-09 (Minimum Output Frequency) or S1-01 (Zero
Speed Level at Stop).
Closed: Output frequency is less than or equal to the value of E1-09 (Minimum Output Frequency) or
S1-01 (Zero Speed Level at Stop).
Closed: Output speed equals the speed reference (plus or minus the hysteresis set to L4-02).
Closed: Output speed and speed reference equal L4-01 (plus or minus the hysteresis set to L4-02).
Closed: Output speed is less than or equal to the value in L4-01 with hysteresis determined by L4-02.
Closed: Output speed is greater than or equal to the value in L4-01 with hysteresis determined by L4-02.
Closed: Power up is complete and the drive is ready to accept an Up/Down command.
Closed: DC bus voltage is below the Uv trip level set in L2-05.
Closed: Drive has entered the baseblock state (no output voltage).
Open: The speed reference is supplied by an external reference (set in b1-01).
Closed: Digital operator supplies the speed reference.
Open: The Up/Down command is supplied by an external reference (set in b1-02).
Closed: Digital operator supplies the Up/Down command.
Closed: An overtorque or undertorque situation has been detected.
Closed: Fault occurred. (excluding CPF00 and CPF01)
Set this value when the terminal is not used or when using the terminal in the pass-through mode.
Closed: An alarm has been triggered, or the IGBTs have reached 90% of their expected life span.
Closed: The drive has received a reset command from the multi-function input terminals or from serial
network, or the digital operator's RESET key has been pressed.
Closed: Timer output.
Closed: When drive output frequency equals the speed reference ±L4-04.
Closed: When the drive output speed is equal to the value in L4-03 ±L4-04.
Closed: When the drive output speed is less than or equal to the value in L4-03 ±L4-04.
Closed: When the output speed is greater than or equal to the value in L4-03 ±L4-04.
Closed: Overtorque or undertorque has been detected.
Closed: Drive is running in the down direction.
Open: Drive has entered the baseblock state (no output voltage).
Description
for a description of
Description
B Parameter Table
Setting
Default: 50
Min: 0
Max: 161
Default: 51
Min: 0
Max: 161
Default: 6
Min: 0
Max: 161
Default: 37
Min: 0
Max: 161
Default: F
Min: 0
Max: 161
B
185