B Parameter Table
b4: Delay Timers
■
No.
Name
Timer Function On-Delay
b4-01
Time
Timer Function Off-Delay
b4-02
Time
b6: Dwell Function
■
No.
Name
b6-01
Dwell Speed at Start
b6-02
Dwell Time at Start
b6-03
Dwell Speed at Stop
b6-04
Dwell Time at Stop
b7: Droop Control
■
No.
Name
b7-01
Droop Control Gain
b7-02
Droop Control Delay Time Used to adjust the responsiveness of Droop Control.
b8: Energy Saving
■
No.
Name
Energy Saving Control
b8-01
Selection
Energy Saving Control
b8-16
Constant (Ki)
Energy Saving Control
b8-17
Constant (Kt)
168
Used to set the on-delay and off-delay times for a digital timer output (H2- = 12).
The output is triggered by a digital input programmed to H1- = 18).
Parameters b6-01 and b6-02 set the speed to hold and the time to maintain that speed
at start.
Parameters b6-03 and b6-04 set the speed to hold and the time to maintain that speed
at stop.
Sets the speed reduction gain applied at a torque reference of 100%. Set as a
percentage of motor base speed.
0: Disabled
1: Enabled
Enter the Energy Saving value (Ki) as specified on the motor name plate. (for IPM
motors only)
Enter the Energy Saving value (Kt) as specified on the motor name plate. (for IPM
motors only)
YASKAWA ELECTRIC TOEP C710616 38H YASKAWA AC Drive-L1000A Quick Start Guide
Description
Description
Description
Description
Setting
Default: 0.0 s
Min: 0.0 s
Max: 3000.0 s
Default: 0.0 s
Min: 0.0 s
Max: 3000.0 s
Setting
Default: 0.0%
Min: 0.0%
Max: 100.0%
Default: 0.0 s
Min: 0.0 s
Max: 10.0 s
Default: 0.0%
Min: 0.0%
Max: 100.0%
Default: 0.0 s
Min: 0.0 s
Max: 10.0 s
Setting
Default: 0.0%
Min: 0.0%
Max: 100.0%
Default: 0.05 s
Min: 0.03 s
Max: 2.00 s
Setting
Default: 0
Min: 0
Max: 1
Default: 0.10
Min: 0.00
Max: 2.00
Default: 1.00
Min: 0.00
Max: 2.00