YASKAWA L1000A Quick Start Manual page 73

Hide thumbs Also See for L1000A:
Table of Contents

Advertisement

Flowchart C: Auto-Tuning for PM Motors
The flowchart below covers Auto-Tuning for permanent magnetic (PM) motors operating with Closed Loop Vector
Control for PM motors.
Set terminals H1-HC and H2-HC if Safe Disable function is used.
Set the Baseblock input (H1-
Select Motor Data Input
Enter the data in to T2-
indicated on the display.
Press the Up key until "Tuning Ready" is
Press the Run key on the digital operator
and wait until Auto-Tuning is finished.
Continue with encoder offset tuning.
Refer to
Flowchart D: PG Encoder Offset Auto-Tuning on page
・ Select Rotational Back EMF Constant Auto-Tuning T2-01=11.
・ Press the Up key.
Press the Run key on the digital operator
and wait until Auto-Tuning is finished.
Open the motor contactor.
Open terminals H1-HC and H2-HC if used during the normal sequence.
Open the Baseblock input (H1-
<1> If an LED operator is used, the display shows "
<2> If an LED operator is used, the display shows "
YASKAWA ELECTRIC TOEP C710616 38H YASKAWA AC Drive-L1000A Quick Start Guide
START
= 8/9) if used.
No
Is the motor data
sheet available?
Yes
T2-01 = 0.
parameters as
displayed.
<1>
No
No
(Alarm or Fault code
(Alarm or Fault code
Tuning
displayed
displayed
Successful?
Yes
("Entry Accepted"
displayed
<2>
Can the motor
No
rotate freely?
Yes (Ropes removed)
= 8/9) if used.
FINISH
".
".
Figure 36 Auto-Tuning for PM Motors
4 Start-Up Programming & Operation
Select Stationary Auto-Tuning
T2-01 = 1.
Enter the data in to T2-
parameters as
indicated on the display.
Press the Up key until "Tuning Ready" is
displayed.
<1>
Close the motor contactor.
72.
YEA_common
Refer to
Auto-Tuning Fault Detection
on page
140.
Remove the Fault/Alarm source and
repeat Auto Tuning.
4
71

Advertisement