YASKAWA L1000A Quick Start Manual page 212

Hide thumbs Also See for L1000A:
Table of Contents

Advertisement

B Parameter Table
U2: Fault Trace
No.
Name
U2-01
Current Fault
U2-02
Previous Fault
Speed Reference at
U2-03
Previous Fault
Output Speed at
U2-04
Previous Fault
Output Current at
U2-05
Previous Fault
Motor Speed at
U2-06
Previous Fault
Output Voltage at
U2-07
Previous Fault
DC Bus Voltage at
U2-08
Previous Fault
Output Power at
U2-09
Previous Fault
Torque Reference at
U2-10
Previous Fault
Input Terminal Status at
U2-11
Previous Fault
Output Terminal Status
U2-12
at Previous Fault
Drive Operation Status
U2-13
at Previous Fault
Cumulative Operation
U2-14
Time at Previous Fault
Soft Starter Output at
U2-15
Previous Fault
Motor q-Axis Current at
U2-16
Previous Fault
Motor d-Axis Current at
U2-17
Previous Fault
Heatsink Temperature
U2-20
at Previous Fault
Peak Hold Current
U2-21
during Fault
Peak Hold Frequency
U2-22
during Fault
<10> The display resolution depends on the rated output power of the drive. Models CIMR-LU20008 to 20033, 40005 to 40018, and
50003 to 50013 display values in 0.01 A units, while models CIMR-LU20047 to 20415, 40024 to 40605, and 50017 to 50200
display values in 0.1 A units.
<29> Setting units are determined by the digital operator display unit selection (o1-03). When o1-03 = 0, the value is set in Hertz. When o1-03 = 4 or
5, the value is displayed in m/s. When o1-03 = 6, the value is displayed in ft/min.
<40> When checking the values of U1-03, U2-05 and U4-13 with the digital operator they are displayed in units of amperes, but when they are
checked using MEMOBUS communications, the monitor value in MEMOBUS communications is: displayed numeric value / 8192 × drive's
rated current (A), from the condition "8192 (maximum value) = drive's rated current (A)".
210
Displays the current fault.
Displays the previous fault.
Displays the speed reference at the previous fault.
Displays the output speed at the previous fault.
Displays the output current at the previous fault.
Displays the motor speed at the previous fault.
Displays the output voltage at the previous fault.
Displays the DC bus voltage at the previous fault.
Displays the output power at the previous fault.
Displays the torque reference at the previous fault.
Displays the input terminal status at the previous fault. Displayed as in U1-10.
Displays the output status at the previous fault. Displayed as in U1-11.
Displays the operation status of the drive at the previous fault. Displayed as in
U1-12.
Displays the cumulative operation time at the previous fault.
Displays the run speed after a soft start when a previous fault occurred. Displayed
as in U1-16.
Displays the q-axis current for the motor at the previous fault. Displayed as in
U6-01.
Displays the d-axis current for the motor at the previous fault. Displayed as in
U6-02.
Displays the temperature of the heatsink when the most recent fault occurred.
Displayed as in U4-08.
Displays the peak current that occurred just prior to the previous fault.
Displays the output frequency when the peak current displayed in U2-21
occurred.
YASKAWA ELECTRIC TOEP C710616 38H YASKAWA AC Drive-L1000A Quick Start Guide
Description
Analog Output
Unit
Level
No signal output
available
No signal output
available
No signal output
0.01%
available
<29>
No signal output
0.01%
available
<29>
No signal output
<10> <40>
available
No signal output
0.01%
available
<29>
No signal output
0.1 Vac
available
No signal output
1 Vdc
available
No signal output
0.1 kW
available
No signal output
0.1%
available
No signal output
available
No signal output
available
No signal output
available
No signal output
1 h
available
No signal output
0.01%
available
<29>
No signal output
0.1%
available
No signal output
0.1%
available
No signal output
1°C
available
No signal output
0.01 A
available
No signal output
0.01 Hz
available