YASKAWA L1000A Quick Start Manual page 157

Hide thumbs Also See for L1000A:
Table of Contents

Advertisement

Wire Gauges and Tightening Torques
Wire gauge and torque specifications are listed in
the wire ends. Refer to the option manuals for the wire size and torque specifications of other options.
Screw
Terminal Signal
Size
A+, A–, B+,
B–, Z+, Z–,
FE, IP, IG
M2
AO, IG, BO,
IG, ZO, IG
Crimp Terminals
Yaskawa recommends using CRIMPFOX 6 by Phoenix Contact or equivalent crimp terminals with the specifications
listed in
Table 48
for wiring to ensure proper connections.
Note: Properly trim wire ends so loose wire ends do not extend from the crimp terminals.
6 mm
d1
d2
(0.24 in.)
L
PG Encoder Cables for PG-B3 Option
Yaskawa recommends using a LMA-B-S185Y (complementary output) for cables running between the PG-B3
Option and the PG as show in
For instructions on wiring the terminal block, refer to
Figure 84
YASKAWA ELECTRIC TOEP C710616 38H YASKAWA AC Drive-L1000A Quick Start Guide
Table
Table 47 Wire Gauges and Tightening Torques
Bare Cable
Tightening
Torque
Applicable
Nm
Gauges
(lb.in.)
mm
2
0.22 to 0.25
0.75
(1.95 to 2.21)
(18 AWG)
Table 48 Crimp Terminal Sizes
Wire Gauge
Phoenix Contact Model
mm
2
AI 0.25 - 6YE
0.25 (24 AWG)
AI 0.25 - 6BU
0.34 (22 AWG)
AI 0.34 - 6TQ
0.5 (20 AWG)
AI 0.5 - 6WH
Figure
92.
TB1
A+ A- B+ B- Z+ Z-
SD FE
3
4
5
6
E
TA1
Figure 92 Wiring PG Encoder Cable
47. For simpler and more reliable wiring, use crimp ferrules on
Recomm.
Applicable
Gauge
Gauges
mm
2
Stranded wire:
0.25 to 1.0
(24 to 17 AWG)
Solid wire:
(20 AWG)
0.25 to 1.5
(24 to 16 AWG)
L
mm (in)
10.5 (13/32)
10.5 (13/32)
12 (15/32)
Table
46.
TB2
IP IG
AO IG BO IG ZO IG
1
2
A
G
B
F
H
PG encoder side
C
E
D
(Pin)
7 Option Card Installation
Crimp Terminals
Recomm.
Gauge
mm
mm
2
2
0.5
0.25 to 0.5
(24 to 20 AWG)
d1
mm (in)
0.8 (1/32)
0.8 (1/32)
1.1 (3/64)
B3
Wire Type
Shielded
twisted pair,
etc.
Shielded
cable, etc.
d2
mm (in)
2 (5/64)
2 (5/64)
2.5 (3/32)
7
155

Advertisement

Table of Contents
loading