F4: Analog Monitor Card (AO-A3)
No.
Name
Terminal V1 Function
F4-01
Selection
F4-02
Terminal V1 Gain
Terminal V2 Function
F4-03
Selection
F4-04
Terminal V2 Gain
F4-05
Terminal V1 Bias
F4-06
Terminal V2 Bias
Terminal V1 Signal Level
F4-07
Selection
Terminal V2 Signal Level
F4-08
Selection
F5: Digital Output Card (DO-A3)
No.
Name
Terminal P1-C1 Output
F5-01
Selection
Terminal P2-C2 Output
F5-02
Selection
Terminal P3-C3 Output
F5-03
Selection
Terminal P4-C4 Output
F5-04
Selection
Terminal P5-C5 Output
F5-05
Selection
Terminal P6-C6 Output
F5-06
Selection
Terminal M1-M2 Output
F5-07
Selection
Terminal M3-M4 Output
F5-08
Selection
DO-A3 Output Mode
F5-09
Selection
YASKAWA ELECTRIC TOEP C710616 38H YASKAWA AC Drive-L1000A Quick Start Guide
Sets the monitor signal for output from terminal V1. Set this parameter to the last
three digits of the desired U- monitor. Some U parameters are available only in
certain control modes.
Sets the gain for voltage output via terminal V1.
Sets the monitor signal for output from terminal V2. Set this parameter to the last
three digits of the desired U- monitor. Some U parameters are available only in
certain control modes.
Sets the gain for voltage output via terminal V2.
Sets the amount of bias added to the voltage output via terminal V1.
Sets the amount of bias added to the voltage output via terminal V2.
0: 0 to 10 V
1: -10 to 10 V
Sets the function for contact output terminals M1-M2, M3-M4, and photocoupler
output terminals P1 through P6.
0: Output terminals are each assigned separate output functions.
1: Binary code output
2: Use output terminal functions selected by parameters F5-01 through F5-08.
Description
Description
B Parameter Table
Setting
Default: 102
Min: 000
Max: 999
Default: 100.0%
Min: -999.9%
Max: 999.9%
Default: 103
Min: 000
Max: 999
Default: 50.0%
Min: -999.9%
Max: 999.9%
Default: 0.0%
Min: -999.9%
Max: 999.9%
Default: 0.0%
Min: -999.9%
Max: 999.9%
Default: 1
Min: 0
Max: 1
Default: 1
Min: 0
Max: 1
Setting
Default: 0
Min: 0
Max: 161
Default: 1
Min: 0
Max: 161
Default: 2
Min: 0
Max: 161
Default: 4
Min: 0
Max: 161
Default: 6
Min: 0
Max: 161
Default: 37
Min: 0
Max: 161
Default: F
Min: 0
Max: 161
Default: F
Min: 0
Max: 161
Default: 0
Min: 0
Max: 2