YASKAWA L1000A Quick Start Manual page 215

Hide thumbs Also See for L1000A:
Table of Contents

Advertisement

No.
Name
U4-31
Car Acceleration Rate
Speed Reference Limit
U4-40
at Rescue Operation
U4-42
Remaining Distance
<35>
U4-43
Minimum Deceleration
Distance
<35>
U4-44
Minimum Stop
Distance
<35>
<29> Setting units are determined by the digital operator display unit selection (o1-03). When o1-03 = 0, the value is set in Hertz. When o1-03 = 4 or
5, the value is displayed in m/s. When o1-03 = 6, the value is displayed in ft/min.
<35> o1-12 (Length Units) determines the units. When o1-12 is set to 0, the unit is millimeters. When o1-12 is set to 1, the unit is inch.
<40> When checking the values of U1-03, U2-05 and U4-13 with the digital operator they are displayed in units of amperes, but when they are
checked using MEMOBUS communications, the monitor value in MEMOBUS communications is: displayed numeric value / 8192 × drive's
rated current (A), from the condition "8192 (maximum value) = drive's rated current (A)".
<41> The MEMOBUS communications data is in 10 h units. If data in 1 h units are also required, refer to register number 0099H.
<42> The MEMOBUS communications data is in 10 h units. If data in 1 h units are also required, refer to register number 009BH.
Note: Fault trace (i.e., the fault history) is not maintained when CPF00, CPF01, CPF06, CPF24, oFA00, oFb00, oFC00, Uv1, Uv2, or
Uv3 occur.
YASKAWA ELECTRIC TOEP C710616 38H YASKAWA AC Drive-L1000A Quick Start Guide
Shows the car acceleration rate.
Displays the speed limit for Rescue Operation based on how much power the
backup battery or UPS has. Displays 0% when Rescue Operation is not being
performed.
Displays the remaining distance according to the stopping method selected.
Displays the Minimum Deceleration Distance calculated by E1-04.
Displays the Minimum Stop Distance calculated by d1-26.
Description
B Parameter Table
Analog Output
Unit
Level
0.01 m/
No signal output
available
s
2
No signal output
1%
available
10 V:
S5-10 = 1: S5-11
1 mm
S5-10 = 2: S5-12
No signal output
1 mm
available
No signal output
1 mm
available
B