YASKAWA L1000A Quick Start Manual page 118

Hide thumbs Also See for L1000A:
Table of Contents

Advertisement

4 Start-Up Programming & Operation
Table 34 Installation of the Inrush Current Suppression Circuit for Battery
Voltage
200 V
400 V
575 V
<1> Select the appropriate relay referring to the following calculation even if the battery voltage or main power current is applied.
Load current of battery (A) =
116
Drive Model
CIMR-LU
20215
20283
20346
20415
40150
40180
40216
40260
40304
40370
40450
40605
50099
50130
50172
50200
Motor rated power (kW) × Operation frequency when running battery (Hz) × 2 × 1000
Battery voltage (Vdc) × 0.6 (Motor efficiency) × Motor rated frequency (Hz)
Resistor
1.0 Ω, 80 W
1.0 Ω, 80 W
1.0 Ω, 80 W
1.0 Ω, 80 W
1.0 Ω, 120 W
1.0 Ω, 220 W
1.0 Ω, 220 W
1.0 Ω, 220 W
1.0 Ω, 220 W
1.0 Ω, 500 W
2.0 Ω, 1000 W
2.0 Ω, 1000 W
2.0 Ω, 220 W
2.0 Ω, 220 W
2.0 Ω, 440 W
2.0 Ω, 440 W
YASKAWA ELECTRIC TOEP C710616 38H YASKAWA AC Drive-L1000A Quick Start Guide
Relay
<1>
YEA_common

Advertisement

Table of Contents
loading