YASKAWA L1000A Quick Start Manual page 194

Hide thumbs Also See for L1000A:
Table of Contents

Advertisement

B Parameter Table
L5: Automatic Fault Reset
No.
Name
Number of Auto Reset
L5-01
Attempts
Fault Output Operation
L5-02
during Auto Reset
Undervoltage Fault Reset
L5-06
Selection
L6: Torque Detection
No.
Name
Torque Detection Selection
L6-01
1
L6-02
Torque Detection Level 1
L6-03
Torque Detection Time 1
Torque Detection Selection
L6-04
2
L6-05
Torque Detection Level 2
L6-06
Torque Detection Time 2
192
Sets the number of times the drive may attempt to reset after the following faults
occur: GF, LF, oC, ov, rr, oH1, oL1, oL2, oL3, oL4, UL3, UL4.
0: Fault output not active.
1: Fault output active during reset attempt.
0: Same as L5-01 condition
1: Always automatically reset UV1
0: Disabled
1: oL3 detection only active during speed agree, operation continues after detection
2: oL3 detection always active during run, operation continues after detection
3: oL3 detection only active during speed agree, output shuts down on an oL3 fault
4: oL3 detection always active during run, output shuts down on an oL3 fault
5: UL3 detection only active during speed agree, operation continues after detection
6: UL3 detection always active during run, operation continues after detection
7: UL3 detection only active during speed agree, output shuts down on an oL3 fault
8: UL3 detection always active during run, output shuts down on an oL3 fault
Sets the overtorque and undertorque detection level.
Sets the time an overtorque or undertorque condition must exist to trigger torque
detection 1.
0: Disabled
1: oL4 detection only active during speed agree, operation continues after detection
2: oL4 detection always active during run, operation continues after detection
3: oL4 detection only active during speed agree, output shuts down on an oL4 fault
4: oL4 detection always active during run, output shuts down on an oL4 fault
5: UL4 detection only active during speed agree, operation continues after detection
6: UL4 detection always active during run, operation continues after detection
7: UL4 detection only active during speed agree, output shuts down on an oL4 fault
8: UL4 detection always active during run, output shuts down on an oL4 fault
Sets the overtorque and undertorque detection level.
Sets the time an overtorque or undertorque condition must exist to trigger torque
detection 2.
YASKAWA ELECTRIC TOEP C710616 38H YASKAWA AC Drive-L1000A Quick Start Guide
Description
Description
Setting
Default: 0
Min: 0
Max: 10
Default: 0
Min: 0
Max: 1
Default: 0
Min: 0
Max: 1
Setting
Default: 0
Min: 0
Max: 8
Default: 150%
Min: 0%
Max: 300%
Default: 0.1 s
Min: 0.0 s
Max: 10.0 s
Default: 0
Min: 0
Max: 8
Default: 150%
Min: 0%
Max: 300%
Default: 0.1 s
Min: 0.0 s
Max: 10.0 s