No.
Name
Rescue Operation Torque
S4-05
Limit
Rescue Operation Power
S4-06
Supply Selection
S4-07
UPS Power
UPS Operation Speed
S4-08
Limit Selection
DC Bus Voltage during
S4-12
Rescue Operation
Rescue Operation Power
S4-13
Supply Deterioration
Detection Level
Speed Reference Selection
S4-15
for Rescue Operation
<39>
<5> Default setting is determined by the control mode (A1-02).
<39> Available in drive software versions PRG: 7016 or later.
S5: Short Floor Operation
No.
Name
Short Floor Operation
S5-01
Selection
Nominal Speed for Short
S5-02
Floor Calculation
Short Floor Minimum
S5-03
Constant Speed Time
Distance Calculation
S5-04
Acceleration Time Gain
Distance Calculation
S5-05
Deceleration Time Gain
S5-10
Stopping Method Selection
S5-11
Deceleration Distance
S5-12
Stop Distance
YASKAWA ELECTRIC TOEP C710616 38H YASKAWA AC Drive-L1000A Quick Start Guide
Sets the torque limit used during Rescue Operation.
0: Battery
1: UPS (single-phase)
2: UPS (3-phase)
Sets the capacity of the UPS.
Determines how a speed limit should be applied to the Rescue Operation speed
(S4-15) when operating from a UPS.
0: Disabled
1: Enabled until Light Load Direction Search is complete
2: Enabled until stop
Sets the DC bus voltage during Rescue Operation.
Determines at which level of backup power supply deterioration a PF5 fault is
triggered.
Selects the speed reference used for Rescue Operation.
0: Disabled
1: Enabled (Short Floor)
2: Enabled (Advance Short Floor)
When d1-18 (Speed Priority Selection) is set to 0 or 3, S5-02 determines the rated
speed used during Short Floor.
Sets the minimum operation time when the Advanced Short Floor function is enabled
(S5-01 = 2).
Set for acceleration jerk compensation in Distance Calculation.
Set for deceleration jerk compensation in Distance Calculation.
0: Disabled
1: Direct Landing
2: Leveling Distance Control
Sets the deceleration distance when Stop Distance Control is enabled.
Sets the stopping distance when Stop Distance Control is enabled.
Description
Description
B Parameter Table
Setting
Default: 100%
Min: 0%
Max: 300%
Default: 0
Min: 0
Max: 2
Default: 0.0 kVA
Min: 0.0 kVA
Max: 100.0 kVA
Default: 2
Min: 0
Max: 2
Default: 0 V
Min: 0 V
Max: 1150 V
Default: 80%
Min: 10%
Max: 100%
Default: 0
Min: 0
Max: 1
Setting
Default: 0
Min: 0
Max: 2
Default: 0.0%
Min: 0.0%
Max: 100.0%
Default: 0.0 s
Min: 0.0 s
Max: 2.0 s
Default: 150.0%
Min: 50.0%
Max: 200.0%
Default: 150.0%
Min: 50.0%
Max: 200.0%
Default: 0
Min: 0
Max: 2
Default: 0 mm
Min: 0 mm
Max: 32767 mm
<36>
Default: 0 mm
Min: 0 mm
Max: 10000 mm
<37>
B
203