B Parameter Table
H4: Analog Outputs
No.
Name
Terminal FM Monitor
H4-01
Selection
H4-02
Terminal FM Gain
H4-03
Terminal FM Bias
Terminal AM Monitor
H4-04
Selection
H4-05
Terminal AM Gain
H4-06
Terminal AM Bias
Terminal FM Signal Level
H4-07
Selection
Terminal AM Signal Level
H4-08
Selection
188
Selects the data to be output through multi-function analog output terminal FM.
Set the desired monitor parameter to the digits available in U-. For example,
enter "103" for U1-03.
Sets the signal level at terminal FM that is equal to 100% of the selected monitor
value.
Sets the bias value added to the terminal FM output signal.
Selects the data to be output through multi-function analog output terminal AM.
Set the desired monitor parameter to the digits available in U-. For example,
enter "103" for U1-03.
Sets the signal level at terminal AM that is equal to 100% of the selected monitor
value.
Sets the bias value added to the terminal AM output signal.
0: 0 to 10 V
1: -10 to 10 V
0: 0 to 10 V
1: -10 to 10 V
YASKAWA ELECTRIC TOEP C710616 38H YASKAWA AC Drive-L1000A Quick Start Guide
Description
Setting
Default: 102
Min: 000
Max: 999
Default: 100.0%
Min: -999.9%
Max: 999.9%
Default: 0.0%
Min: -999.9%
Max: 999.9%
Default: 103
Min: 000
Max: 999
Default: 50.0%
Min: -999.9%
Max: 999.9%
Default: 0.0%
Min: -999.9%
Max: 999.9%
Default: 0
Min: 0
Max: 1
Default: 0
Min: 0
Max: 1