4 Start-Up Programming & Operation
Using Separate Batteries for DC Bus and Control Power Supply, DC Bus Battery under 250 Vdc (500 Vdc, 720
Vdc)
Follow these instructions when using separate batteries for Rescue Operation with the battery for the DC bus having a
lower voltage than 250 Vdc for 200 V class drives, 500 Vdc for 400 V class drives, or 720 Vdc for 600 V class drives.
Follow the wiring diagram shown in
to the L1000A, use the 1.1 m cable packaged with the product. The connector cover must first be removed in order to
access connection port CN19 for the battery. Refer to
Wiring for CIMR-LU20008 to 20180, 40005 to 40112, and 50003 to 50077
Figure 45
YEA_common
Battery for DC bus
200 V Class: 48 to 250 Vdc
400 V Class: 48 to 500 Vdc
600 V Class: 48 to 720 Vdc
200 V Class: 250 to 340 Vdc
400 V Class: 500 to 680 Vdc
600 V Class: 720 to 850 Vdc
Operation Sequence
Starting Rescue Operation
1.
Open contactor B and wait at least 5 seconds.
2.
Set the input terminal programmed for Rescue Operation (H1- = 55).
3.
Close contactors A and C.
4.
Set the Up/Down command.
Ending Rescue Operation
1.
After the car has stopped, open contactors A and C.
2.
Clear the input terminal set for Rescue Operation (H1- = 55).
3.
Wait at least 0.5 s and then close contactor B to return to operation with normal power supply.
114
Figure 52
to
Figure
Magnetic Contactor A
DC bus power supply
L1
L2
L3
Magnetic Contactor B
Magnetic Contactor C
Battery for
control circuit
H1-
= 55
(Rescue Operation)
Magnetic Contactor Sequence
Magnetic Contactor B
5 s
Magnetic Contactor A
Magnetic Contactor C
H1-
= 55
(Rescue Operation)
Figure 52 Wiring Two Batteries for DC Bus and Control Power Supply
(DC Bus Battery is less than 250 Vdc (500 Vdc, 720 Vdc))
54. When connecting the battery for the control power supply
Connecting the Drive and Battery on page 122
B2
B1
+1
+2
R/L1
S/L2
T/L3
-
Power supply
CN19
1
4
S3 to S8
SC
YASKAWA ELECTRIC TOEP C710616 38H YASKAWA AC Drive-L1000A Quick Start Guide
L1000A
U/T1
V/T2
W/T3
Control
circuit
0.5 s
for details.