ANIMAS® VIBE™ SYSTEM
C H AP TE R 9 - AD V AN C ED F EA TU R E S / SE TU P A N D A CT IV AT I ON
Setup Advanced Screen 1 – Personal Settings - Insulin Sensitivity Factor (ISF)
An Insulin Sensitivity Factor (ISF) is the amount you can expect to lower your BG with one unit of
insulin. Your HCP may recommend you use different Insulin Sensitivity Factors (ISFs) for different times
of the day. When you use the ezCarb or ezBG feature, your pump will automatically select the ISF for
the current time stored in the pump.
This screen allows you to set different ISFs for 12 different time slots.
NOTE: If you set only one Insulin Sensitivity Factor, it will be used for the entire 24-hour period.
m
WARNING: ALWAYS review changes in your pump settings with your HCP to make sure they
are correct. Incorrect settings can result in under delivery or over delivery of insulin and result in
serious injury or death.
SETUP ADV 1
I:C Ratio
ISF
BG Target
Home
2.
The first segment always starts at midnight. The last time slot available
is 11:30pm. Use the
3.
Press
to change to flashing cursor for Edit mode.
4.
Use the
/
5.
Press
when setting is made.
6.
To move to the next ISF screen, scroll to "
7.
Scroll up to the "Time" field and press
Edit mode.
8.
Use the
/
9.
Scroll to the "1U:" (mg/dL units) field and press
cursor for Edit mode.
10.
Use the
remaining segments per your HCP's recommendations.
To review your settings, highlight "
times and setting values are correct.
When finished, scroll to "Done" and press
To return to the Home screen, scroll to "Home" and press
P130007
41028900 RevB_OB_VIBE_US_EN_MG_R4.indd 49
1.
From the SETUP ADV 1 screen, scroll up to "ISF". Press
/
buttons to scroll to the "1U:" (mg/dL) field.
buttons to change to desired setting.
buttons to change the segment start time. Press
/
buttons to change the "1U:" (mg/dL units) field as desired. Press
" and press
" and press
.
to change to flashing cursor for
.
to change to flashing
to scroll through each segment. Confirm the
to return to the SETUP ADV 1 screen.
.
49
Dec 2014
.
ISF
1 of 12
Time:
12:00A
1U:
40
mg/dL
Done
Home
ISF
2 of 12
Time:
6:00A
1U:
50
mg/dL
Done
Home
. Repeat to set
A157 of A312
11/14/14 2:52 PM