ANIMAS® VIBE™ SYSTEM
C H AP TE R 10 - USI N G A D VA N CE D F EA TU R ES
6.
The ezBG Total screen is displayed and the suggested bolus amount from
your ezBG Bolus appears in the "Total" field. Above the "Total" field are the
two parts that are used in calculating the suggested "Total" amount. BG refers
to the BG correction amount calculated from the previous ezBG screen. IOB
refers to the Insulin on Board amount from a previous bolus.
Below the suggested amount "Total" is the bolus amount entry field where
you can choose to deliver the suggested amount or adjust the amount as
needed. This field will display 0.00U, and will be highlighted and flashing.
Press the
button once to change the amount to match the suggested
bolus amount. Then use the
When you have the desired delivery amount displayed, press
highlighted, press
NOTE:
• If the BG amount on the ezBG Total screen is a negative number, the
suggested "Total" amount will be set to 0.00U.
• Calculated total units will be rounded to the nearest .05 units.
• If the maximum bolus limit you set in Advanced Features is less than the
suggested "Total" bolus amount on the Bolus Total screen, the bolus
amount entry field will change to that limit (rather than the suggested
"Total" amount) when you press the
7.
If you are using the Dexcom G4 PLATINUM Sensor and Transmitter
with your pump, you will be prompted on the display after the bolus is
delivered to decide if the BG value you just entered should be used to
calibrate your CGM (see Chapter 5 in Section II). Select "Yes" and press
to use this BG value for CGM calibration. If the pump display times out
before you select "Yes", the BG value will not be used for CGM calibration.
NOTE:
• If you enter a BG amount below 70 mg/dL or above
250 mg/dL, your pump will alert you that you have
entered an out of range BG. To confirm the Alert,
press
. Your pump will still use the out of range
BG value in ezCarb and ezBG bolus calculations,
but treat the out of range BG as prescribed by your
HCP.
• The LOW BG and HIGH BG Alerts discussed here are different than the Low and High Glucose Alerts
that apply only to CGM readings when using the Dexcom G4 PLATINUM Sensor and Transmitter with
your pump. See Chapter 2 in Section II for more information on CGM Alerts.
P130007
41028900 RevB_OB_VIBE_US_EN_MG_R4.indd 75
/
buttons to adjust the amount if necessary.
to deliver the bolus.
button once.
. With "Go"
Alert
LOW BG
Treat low BG.
No bolus
recommended.
Monitor BG.
Confirm
75
Dec 2014
ezBG Total
BG
+
2.71U
IOB
- -.- - U
Total =
2.70U
U
0.00U
0.00
Go
Main Menu
ezBG Total
BG
+
2.71U
IOB
- -.- - U
Total =
2.70U
2.70U
Go
Main Menu
DELIVERING
U
2.70
Press any
function button
to cancel.
Use BG
For CGM
Calibration?
Must Be A
Fingerstick
Yes
N0
Alert
HIGH BG
Treat high
BG.
Check site.
Check
ketones.
Monitor BG.
Confirm
A183 of A312
11/14/14 2:53 PM