7. Remove the fan and the mounting plate.
8. Pull up on the 4 rubber isolators to separate the fan from the mounting plate.
9. To reinstall the fan, perform the steps in reverse order. When reinstalling the fan, make sure the air flow
directional arrow faces outward.
3.32

Integrator Assembly

NOTICE: The integrator rod glass should be flush with the output aperture with the black finish. If the glass is
damaged, contact Christie Technical Support staff immediately. Always wear gloves when you handle the inte-
grator assembly.
The integrator assembly is mounted in the light tube of the IOS. It runs through a firewall cutout that separates
the lamp housing from the light engine.
1. Turn the lamp off and cool the projector for at least 15 minutes.
2. Turn the projector off and then disconnect it from AC power.
3. Remove the top lid. See
4. Remove the service door. See
5. Remove the 6 integrator housing screws.
6. Remove the housing.
7. Remove the 2 rotational integrator adjustment screws.
8. Slide the integrator rod back and tilt it to remove it from the casting.

3.32.1 Remove the Contrast Aperture

The contrast aperture is located after the fold mirror in the light path within the IOS.
1. Turn the lamp off and cool the projector for at least 15 minutes.
2. Turn the projector off and then disconnect it from AC power.
3. Remove the top lid. See
4. Remove the lens surround.
5. Remove the front skin. See
+
Solaria One/Solaria One
Service Manual
020-101039-02 Rev. 1 (06-2013)
Remove the Top Lid on page
Remove the Service Door on page
Remove the Top Lid on page
Remove the Front Skin on page
Section 3: Parts and Module Replacement
3-4.
3-8.
3-4.
3-4.
3-33