optimal lens performance (i.e. factory setup of absolute lens distance to the prism). It is
critical that you count each turn of the cap screws to ensure accurate adjustment.
Typically, horizontal boresight does not require adjustment. It should only be adjusted if a large horizontal
angular offset to the screen is required.
1. Remove the lens surround.
2. Display the DC2K Framing test pattern:
a. On the touch panel controller (TPC), tap the Test Pattern icon (
b. Tap All Test Patterns.
c. Tap DC2K Framing.
3. Loosen the right boresight set screw (B).
4. Turn the right boresight cap screw (A) 1/16 of a turn clockwise.
5. Adjust the left boresight cap screw (C) equally in the opposite direction.
6. If the quality of the projected image has not improved, turn the right boresight cap screw 1/16 of turn
counter-clockwise. Make sure the left adjuster is adjusted equally in the opposite direction.
+
Solaria One/Solaria One
Service Manual
020-101039-02 Rev. 1 (06-2013)
Only adjust horizontal boresight 1/8 of a turn or less at one time to maintain
A
B
A
B
C
D
Right Boresight Cap Screw
Right Boresight Set Screw
Left Boresight Cap Screw
Left Boresight Set Screw
Section 2: Adjust the Image
in the task bar.
)
C
D
2-5