a. On the touch panel controller (TPC), tap the Test Pattern icon (
b. Tap All Test Patterns.
c. Tap RBG-12bit-Full Screen White.
5. Measure the color point of the pattern with the spectroradiometer and verify that the values are within
these tolerances:
If the values are outside the tolerances:
a. Remove the top lid. See
b. Remove the screw holding the yellow notch filter cover.
Note: Two different yellow notch filter assemblies are used in the Solaria One and Solaria One
jectors; version A and version B. Version B allows greater adjustment of the yellow notch filter and a
cut out holds the adjustment lever in position.
c. Adjust the position of the yellow notch filter:
• For version A, loosen the set screw and then manually rotate the yellow notch filter. Tighten the set
screw when the adjustment is complete.
• For version B, loosen or tighten the set screw to increase or decrease the angle of the yellow notch
filter.
+
Solaria One/Solaria One
Service Manual
020-101039-02 Rev. 1 (06-2013)
Color
X
Red
0.640
Green
0.280
Blue
0.160
White
0.314
Remove the Top Lid on page
Tolerance
Y
+/- 0.002
0.320
+/- 0.002
0.640
+/- 0.002
0.100
+/- 0.002
0.351
3-4.
Section 2: Adjust the Image
in the task bar.
)
Tolerance
+/- 0.002
+/- 0.002
+/- 0.002
+/- 0.002
pro-
+
2-9