Section 3: Parts and Module Replacement
4. Complete these fields:
Type
Serial Number
Reason for Change
Lamp Expiry (Hours)
Hours Used
5. Tap Save.
6. Tap Next.
7. Align the lamp. See
3.15

Remove the Lens

1. Tap and hold the red power button
2. Allow the lamp to cool for a minimum of 15 minutes.
3.
the projector from AC power or turn the circuit breaker off.
Disconnect
4. Remove the lens surround.
5. Install the lens cap and turn the lens clamp to the open position with a hex key.
6. If necessary, remove the 2 cap screws securing the lens to the lens mount using a hex key.
7. Pull the lens out of the lens mount and then install a small lens cap on the rear of the lens.
8. Remove the small rear cap from the new lens. Keep the front cap on.
9. Align the tabs on the lens plate with the lens mount. Insert the lens until it connects with the magnets on the
mount. When the lens contacts the magnetic plates it is seated correctly.
10. Secure the lens clamp by rotating it clockwise with a hex key.
11. Install the lens mount cap screws for added stability.
12. Replace the lens surround.
13. Remove the lens cap from the front of the lens.
3-14
Field
The lamp type.
The lamp serial number.
The reason the lamp was changed.
The number of hours the lamp can operate before replacement.
The number of hours the lamp has operated before installation.
Align the Lamp on page
Description
2-10.
on the TPC Main panel to turn the lamp and projector off.
+
Solaria One/Solaria One
Service Manual
020-101039-02 Rev. 1 (06-2013)