Adjust Vertical Boresight Angle - Christie Solaria One Service Manual

Hide thumbs Also See for Solaria One:
Table of Contents

Advertisement

5. If the black corner remains, insert a hex driver in the second set screw (C) and a hex driver in the second
cap screw (D).
6. Equally turn the set screw (A) and cap screw (B) in opposite directions until the black corner is removed.
7. Replace the top lid.
2.3

Adjust Vertical Boresight Angle

focused uniformly on the screen by aligning the projector to the screen and focusing the lens.
When adjusting boresight, you must maintain the boresight distance from the lens to the
prism plane set by Christie. For example, when you move the top screw outward, turn the
bottom two boresight screws to maintain the overall distance.
optimal lens performance (i.e. factory setup of absolute lens distance to the prism). It is
critical that each turn of the cap screws is tracked to ensure adjustments are accurate.
It is recommended that you complete a top and bottom boresight adjustment before adjusting the horizontal
boresight.
1. Remove the lens surround.
2. Display the DC2K Framing2 test pattern:
a. On the touch panel controller (TPC), tap the Test Pattern icon (
b. Tap All Test Patterns.
c. Tap DC2K Framing 2.
+
Solaria One/Solaria One
Service Manual
020-101039-02 Rev. 1 (06-2013)
A boresight adjustment should only be made when the image cannot be
Only adjust vertical boresight 1/8 of a turn or less at one time to maintain
C
Set Screw (x2)
D
Cap Screw (x2)
Section 2: Adjust the Image
in the task bar.
)