d. Repeat steps 4 and 5. Replace the yellow notch filter if these corrective measures do not work.
e. Replace the yellow notch filter cover.
f. Replace the top lid.
6. Repeat steps 4 and 5 for the RBG-12bit-Full Screen Red, Green, and Blue test patterns.
2.6

Align the Lamp

You must adjust the lamp position whenever you install a lamp. Before you adjust the lamp, turn the lamp on
and open the douser.
1. Tap Menu > Advanced Setup > Lamp Power.
2. Verify the value in the Power% field is at a level suitable for your requirements.
3. Tap Menu > Advanced Setup > Light Adjust.
4. Record the number in the Intensity field.
5. Tap Display Full Screen White Test Pattern.
6. Complete a coarse lamp adjustment:
a. Locate the Y axis adjustment label on the operator side of the projector.
b. Insert a 5 mm hex driver (A) through the louvers at an angle below the Y axis adjustment label until it
is firmly seated on the Y axis adjustment screw (B).
c. Turn the screw clockwise or counterclockwise until the value in the Intensity field peaks and then
reduces.
d. Remove the hex driver and repeat steps a to c to adjust the Z and X axis.
7. Allow the lamp to warm for a minimum of 10 minutes.
8. Complete a fine lamp adjustment:
a. Locate the Y axis adjustment label on the operator side of the projector.
2-10
B
A
Solaria One/Solaria One
+
Service Manual
020-101039-02 Rev. 1 (06-2013)