Section 5: Troubleshooting
DMD Over-temperature Warning
• Tap Menu > Status and then Temperatures in the left pane. Verify if the DMD temperatures are too high. If
the temperatures are too high, turn the lamp off and allow the cooling fans to cool the projector.
• Check the condition of the air filters and clean or replace them if they appear to be dirty.
• Verify that all fans are operating.
5.2

Lamp Functionality

Lamp Does Not Ignite
• Tap Menu > Advanced Setup > Lamp History and verify the number of hours the lamp has operated.
Replace a lamp nearing the end of its operational life.
• Tap Menu > Status and then Interlocks in the left pane. Check and correct all interlock failures.
• Tap Menu > Status and then All Alarms in the left pane. If a ballast communication error has occurred,
restart the projector and turn the lamp on.
• Tap Menu > Status and then Temperatures in the left pane. Verify if the DMD temperatures are too high. If
the temperatures are too high, turn the lamp off and allow the cooling fans to cool the projector. Ensure the
projector is properly ventilated and the air filters are not blocked.
• Listen for a clicking noise that indicates the ballast is attempting to strike the lamp. If you do not hear a click-
ing noise, there might be a problem with the ballast. Contact a Christie accredited service technician to
resolve the issue.
• If you hear a brief clicking noise, but the lamp does not ignite, replace the lamp.
Lamp Suddenly Turns Off
• Tap Menu > Advanced Setup > Lamp Power/LiteLOC Setup. Increase the lamp power.
• Tap Menu > Status and then Interlocks in the left pane. Review and correct all interlock failures.
• Tap Menu > Status and then Temperatures in the left pane. Verify if the DMD temperatures are too high. If
the temperatures are too high, turn the lamp off and allow the cooling fans to cool the projector. Ensure the
projector is properly ventilated and the air filters are not blocked.
• Replace the lamp.
LiteLOC
Not Working
• Tap Menu > Advanced Setup > LampPower/LiteLOC™ Setup. Tap Enable LiteLOC
• If the lamp power is at the maximum setting to maintain a LiteLOC™ setting, LiteLOC™ is automatically
disabled. Reduce the LiteLOC™ setting, or install a new lamp.
5.3

Display Issues

No Image Appears
• Make sure the lamp is on.
• Make sure the douser is open.
• Make sure a white test pattern is selected.
• Make sure the service doors are closed.
• Verify the marriage icon on the main window of the touch panel controller (TPC) is green.
5-2
.
+