Section 3: Parts and Module Replacement

3.31.2 Remove the Cathode Lamp Blower (Fan 2)

EXPLOSION HAZARD! Always wear protective safety clothing and a face shield when
performing service with the service safety shield removed and a lamp installed.
The cathode lamp blower is located at the rear of the projector, behind the lamp access door.
Note: When replacing the cathode lamp blower, you must replace the anti-tamper label on the side of the lamp
blower assembly.
1. Turn the lamp off and cool the projector for at least 15 minutes.
2. Turn the projector off and then disconnect it from AC power.
3. Remove the anode blower firewall. See
4. Remove the 3 screws holding the lamp adjust cable plate to the blower.
5. Loosen the set screws securing the flexible shafts to the lamp adjust and then disconnect the flexible shafts.
6. Remove the 2 screws securing the internal touch panel controller (TPC) harness.
3-30
Remove the Anode Lamp Firewall on page
3-15.
+