Checking/Clearing The Transfer Count; Checking Toner Motor Operation - Kyocera TASKalfa 2551ci Service Manual

Hide thumbs Also See for TASKalfa 2551ci:
Table of Contents

Advertisement

Item No.
U127

Checking/clearing the transfer count

Description
Displays and clears the counts of the transfer counter.
Purpose
To check the count after replacement of the
counts after replacing transfer roller.
Method
1. Press the start key. The current counts of the transfer counter is displayed.
Mid Trans(Cnt)
2nd Trans(Cnt)
Clearing
1. Select [Clear].
2. Press the start key. The counter value is cleared.
Clears only the transfer roller. The transfer belt unit is not cleared.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.

Checking toner motor operation

U135
Description
Drives toner motors.
Purpose
To check the operation of toner motors.
Remarks
When driving the toner motors long time or several times, developer section becomes the toner
full and is locked.
Method
1. Press the start key.
2. Select [Toner].
3. Press the start key. The operation starts.
Toner
4. To stop the operation, press the stop key.
Completion
Press the stop key after operation stops. The screen for selecting a maintenance item No. is dis-
played.
Display
Transfer belt unit counter value (Cnt)
Transfer roller counter value (Cnt)
Display
Toner motor (TM) is turned on
Description
transfer belt unit or
Description
Description
1-3-74
transfer roller. Also to clear the
2NP