Code
6311
DF middle eject sensor stay
jam
6401
DF tray upper surface sen-
sor non arrival jam
6411
DF tray upper surface sen-
sor stay jam
6511
DF eject paper sensor stay
jam
6811
DF side registration sensor 1
stay jam
6911
DF side registration sensor 2
stay jam
7001
DF staple operation error
7100
CF paper entry sensor non
arrival jam
7901
HP detection error of a mid-
dle motor
7951
Paper interval error jam
9000
No paper feed from DP
9001
DP original conveying jam
9002
DP sensor stay jam
9004
DP original switchback jam
9005
No original feed jam 2
*: Refer to figure 1-4-1 for paper jam location (see page 1-4-1).
Contents
DF middle eject sensor (DFMES) is not turned off
within specified time of its turning on (1000-sheet
finisher).
DF tray upper surface sensor (DFTUSS) does not
turn on within specified time of DF middle eject
sensor (DFMES) turning on (1000-sheet finisher).
DF tray upper surface sensor (DFTUSS) is not
turned off within specified time of its turning on
(1000-sheet finisher).
DF eject paper sensor (DFMTS) is not turned off
since the bundle discharge starts (1000-sheet fin-
isher).
DF side registration sensor 1 (DFSRS1) is not
turned off within specified time after driving the DF
side registration motor 1 (DFSRM1) (1000-sheet
finisher).
DF side registration sensor 2 (DFSRS2) is not
turned off within specified time after driving the DF
side registration motor 2 (DFSRM2) (1000-sheet
finisher).
DF staple sensor (DFSTS) is not turned on within
specified time after driving the DF staple motor
(DFSTM) (1000-sheet finisher).
CF paper entry sensor (CFPES) is not turned on
even if a specified time has elapsed after the
machine eject signal was received.
DF middle sensor (DFMES) is not turned on.
An illegal inter-page or inter-copy interval has
occurred (1000-sheet finisher).
DP feed sensor (DPPFS) does not turn on during
original feed from DP (Retry 5 times).
DP timing sensor (DPTS) turns off within the speci-
fied time since the sensor turns on.
Sensor in the conveying system is on since original
feeding starts.
During duplex switchback scanning, the DP regis-
tration sensor (DPRS) does not turn on within
specified time of the DP timing sensor (DPTS)
turning off.
DP lift sensor 1 (DPLS1) does not turn on within
specified time of the lift plate rising.
Conditions
1-4-10
2NP
Jam
location*
J
J
J
J
J
J
J
J
J
J
G
G
G
G
G