[When DP junction PWB is not used]
6. Fit the mount plate B to the copy guard
PWB using the screw.
7. Insert the FFC into the copy guard PWB
until it clicks in.
WIthout a DP junction PWB:
A FFC is used at YC2
(serigraphed on MAIN)
8. Fit the copy guard PWB by hooking to
two hooks of the IH cover and using the
screw M3 x 6.
FFC(long)
Copy guard PWB
1-2-57
Mount plate B
YC2(MAIN)
Figure 1-2-78
Hook
Copy guard PWB
Hook
Figure 1-2-79
2NP-1
Screw
Screw