6.1.1

Displaying and Changing Parameter Values

NVRAM configuration parameter values are viewed and modified using the
commands listed in
TABLE 6-1
Command
printenv parameter
setenv parameter value
set-default parameter
set-defaults
reset-all
password
6-2
Sun Blade 1500 Service, Diagnostics, and Troubleshooting Manual • December 2004
.
TABLE 6-1
NVRAM Parameter Configuration Commands
Description
Displays the current value for the parameter.
If no parameter is provided, all parameters, their current
value, and their default value are displayed.
Set parameter to value. Values are typically textual or
numeric. Changes made with the setenv command are
permanent, but require a reset or power cycle to take affect.
Resets the parameter to the default value.
Resets all parameters to their default values.
Initiates a warm boot where most NVRAM configuration
parameters are read. With power cycling or a cold boot, all
NVRAM configuration parameters are read.
Sets the security-password