The power supply output voltages are listed in the following table. The power
supply continues to regulate all outputs for 20 milliseconds after AC power is
removed.
TABLE C-14
Output
1
2
3
4
5
Note – The combined power of output 1 and output 3 must be less than 600 watts.
C.2.1

Control Signals

With the exception of the PowerOn signal, all power supply control signals are at
TTL signal levels.
TABLE C-15
Parameter
V
(high-level output voltage)
OH
V
(low-level output voltage)
OL
V
(high-level input voltage)
IH
V
(low-level input voltage)
IL
C.2.1.1

Remote Enable PowerOn

A remote interface can enable the DC outputs with a low signal to the PowerOn
input. Both signals are interfaced to the power supply through the motherboard.
-36
Sun Ultra 80 Service Manual • March 2000
Power Supply Output Values
Voltage (VDC)
3.3
5.0
12.0
-12.0
5.0
Power Supply Control Signal
Max Current (A)
90.0
70.0
8.0
0.4
1.5
Min
2.4 VDC
2.0 VDC
Regulation Band
3.23 to 3.43
4.85 to 5.25
11.65 to 12.60
-12.60 to -11.40
4.75 to 5.25
Max
0.4 VDC
0.8 VDC