Table 9-2 Steps To Test Components In Functional Mode - Sun Microsystems Blade 1500 Service, Diagnostics, And Troubleshooting Manual

Table of Contents

Advertisement

Note – If you are going to test the optical drive, insert a known good optical media
disc into the drive before starting SunVTS. If a file manager window opens for the
disc, close it.
1. As superuser, open a terminal window and start the SunVTS software:
# /opt/SUNWvts/bin/sunvts
The SunVTS GUI is displayed.
2. From Select Test Mode, check Functional.
3. From System Map, check Logical.
4. From the Options menu, select Test Execution and set Max Passes to 1.
To exercise the component more, set for more passes. Use the time for one pass in
TABLE 9-2
5. Click Apply.
6. From Select Devices, check None.
Note – If testing a component requires checking Intervention, uncheck the box
when you have finished testing that component.
7. Use
TABLE 9-2
test.
Steps to Test Components in Functional Mode
TABLE 9-2
Component
Steps to Take
Hard drive
8. Click the plus sign adjacent to IDE - Devices(uata0).
9. Select c0t0d0(disktest) for HDD0 or c0t1d0(disktest) for
10.Click Reset.
11.Click Start.
Optical drive
8. From Select Devices, check Intervention.
9. Click the plus sign adjacent to IDE - Devices(sd0).
10.Select c0t2d0s2(cddvdrwtest), c0t2d0s2(dvdtest), or
11.Click Reset.
12.Click Start.
to determine your total test time.
for the next steps, depending upon which component you want to
HDD1.
c0t2d0s2(cdtest).
Approximate
Time for 1 Pass
600+ seconds
Note: This
test is stopped
by clicking
Stop.
85 seconds
Chapter 9 SunVTS
9-7