Configuring Openboot Diagnostics; Initiating A Test; Test Output - Sun Microsystems Blade 1500 Service, Diagnostics, And Troubleshooting Manual

Table of Contents

Advertisement

8.2.3

Configuring OpenBoot Diagnostics

OpenBoot Diagnostics is configurable, and for the simplest testing, follow this
procedure.
1. At the obdiag prompt, set the diagnostic passes to 1. Type:
obdiag> setenv diag-passes 1
2. Set the diagnostic level to maximum. Type:
obdiag> setenv diag-level max
3. Set the diagnostics to be verbose and display subtest names during test execution.
Type:
obdiag> setenv test-args verbose,subtests
These settings are stored in the NVRAM test-args parameter and survive power
cycling.
Note – The help command provides additional information for configuring
OpenBoot Diagnostics.
8.2.4

Initiating a Test

Select a test by typing test and the diagnostic's corresponding number listed in the
menu and press Return. Using the previous examples:
obdiag> test 5
This initiates the diagnostics of the IDE interface.
8.2.5

Test Output

When OpenBoot Diagnostics runs a test, output is displayed.
Chapter 8 OpenBoot PROM
8-7