Installation and Configuration

2.1.1. Control Supply Connections

N O T E : This product requires two power supply connections. The Motor Supply and Control Supply
must both be connected for proper operation.
The control power supply input allows the Ensemble HPe 150/200 to maintain communications if the motor
power is removed, such as in an Emergency Stop condition. The control power supply requires a minimum of
85 VAC input to operate properly. The AC1 input is internally fused. The AC2 input is not internally fused but
can be connected to a voltage source other than Neutral if an external 2 A time-delay fuse is used.
Although the control power supply contains an internal filter, an additional external filter located as close as
possible to the Ensemble HPe 150/200 may be required for CE compliance (Aerotech recommends
Schaffner FN2080).
Neutral (N)
Table 2-1:
Control Supply AC Input Wiring
Pin
AC1
Line (L): 85-240 VAC Control Power Input
AC2
Neutral (0V) or 85-240 VAC Control Power Input with external fuse
Protective Ground (Required for Safety)
www.aerotech.com
Line (L)
Line Filter
Ground

Figure 2-1:

Control Supply Connections
Description
Chapter 2
Ensemble HPe 150/200
DANGER!
High Voltage
TB101
AC1
AC2
1
2
Recommended Wire
Size
2
0.8 mm
(#18 AWG)
2
0.8 mm
(#18 AWG)
2
0.8 mm
(#18 AWG)
13