Ensemble HPe 150/200
N O T E : The user is responsible for providing fuse protection for the brake circuit.
Figure 3-3
is an example of a +24 VDC Brake connected to TB301. In this example, JP3 must be set 1-3 and
all other jumpers removed. Otherwise, the user must connect J207 pin 13 to J207 pin 25. In this case, J207
would function as an interlock to prevent the Brake from releasing if the Motor Feedback connector is not
connected.
1A
+
24VDC
-
-
BRAKE
2
+
70
-IO/-IOH BOARD
TB301-1 NC
TB301-2 C
TB301-3 NO
BRAKE-
J207-13
BRAKE+
J207-25
CHANGE JUMPERS TO:
1
JP3 1-3 IN, 1-2 OUT, 3-4 OUT, 5-6 OUT, 7-8 OUT
VARISTOR: AEROTECH P/N ECR181
2
Figure 3-3:
Brake Connected to TB301
Chapter 3
-IO Expansion Board
NC
JP3-A
RLYV23026SMT
2
1
JP3-B
4
3
JP3-C
6
5
JP3-D
1
8
7
HARRIS P/N: V33ZA1
www.aerotech.com
+5V