2.5.7. Analog Input 0 (J205)

Analog Input 0 is a 16-bit differential input that accepts a voltage in the range of ±10 V with a resolution of 305
µV. Signals outside of this range may damage the input. To interface to a single-ended (non-differential)
voltage source, connect the signal common of the source to the negative input (pin 14, ANALOG_IN-) and
the analog source signal to the positive input (pin 13, ANALOG_IN+). A floating signal source should be
referenced to the signal common (pin 23, AGND) as shown in
Table 2-30:
Analog Input Connector Pin Assignment (J205)
Pin#
Description
13
Analog Input 0 + (Differential)
14
Analog Input 0- (Differential)
23
Analog Common
+
Signal
Source
-
56
ANALOG0 IN+
J205-13
Shielded
Cable
ANALOG0 IN-
J205-14
ANALOG GND
J205-23
A
Figure 2-35:
Chapter 2
Installation and Configuration
Figure
2-35.
1K
1K
A
Analog Input 0 (J205)
In/Out/Bi
Input
Input
-
+12V
-
+
AD622
A
-12V
www.aerotech.com