Electrical Installation; Power Input (Tb101); Figure 2-1: Power Input Connections; Table 2-1: Power Supply Wiring (Tb101) - Aerotech Ensemble QL Hardware Manual

Table of Contents

Advertisement

Installation and Configuration

2.2. Electrical Installation

The Ensemble QL has one AC input power connector. For a complete list of electrical specifications, refer to
Section 1.1. Electrical
Specifications.

2.2.1. Power Input (TB101)

AC input power to the QL is applied to the Input Power (TB101) connector.
The connection requires a minimum of 100 VAC input to operate properly. The AC1 and AC2 inputs are
internally fused.
Figure 2-1
Table 2-1:
Power Supply Wiring (TB101)
Pin
Description
AC1
100 - 240 VAC Input Range
AC2
100 - 240 VAC Input Range
Protective Ground (Required for Safety)
Type
3-Pin Terminal Block
20
shows the required connections to the control power input.
POWER INPUT
AC1
AC2
TB101
100-240V~
50/60Hz
2A MAX
Figure 2-1:
Power Input Connections
Aerotech P/N
Phoenix P/N
ECK00213
Chapter 2
Ensemble QL Hardware Manual
Screw Torque
Value: Nm
1754465
0.5 - 0.6
Recommended Wire Size
2
1.3 mm
(#16 AWG)
2
1.3 mm
(#16 AWG)
2
1.3 mm
(#16 AWG)
Wire Size:
2
AWG [mm
]
12-30 [3.3 - 0.516]
www.aerotech.com