Buell 2009 XB Series Service Manual page 571

Table of Contents

Advertisement

HOME
NOTE
Seal plugs (6) are installed through the wire seals of unused
chambers. If removed, seal plugs must be replaced to seal the
connector.
5.
Install internal seal (4) on lip of socket housing, if removed.
6.
Insert tapered end of secondary locking wedge (5) into
socket housing and press down until it snaps in place. The
wedge fits into the center groove within the socket housing
and holds the terminal latches tightly closed.
NOTES
See
Figure
A-14. While rectangular wedges do not require
a special orientation, the conical secondary locking wedge
of the 3-place connector must be installed with the arrow
(1) pointing toward the external latch.
If the secondary locking wedge does not slide into the
installed position easily, verify that all terminals are fully
installed in the socket housing. The lock indicates when
terminals are not properly installed by not entering its fully
installed position.
sm00009
Figure A-13. Deutsch Connector: Remove Secondary
Locking Wedge
sm00018
1. Arrow on socket locking wedge
2. Arrow on pin locking wedge
Figure A-14. Deutsch Connector: 3-Place Locking Wedges
2009 XB Service: Appendix A Connector Repair A-9
2
1

Advertisement

Table of Contents
loading

Table of Contents