sm00013
5
7
1
4
8
1. Latch
2. Secondary lock open
3. Pin housing
4. Socket housing
5. Pin terminal
6. Socket terminal
7. Tang (pin)
8. Tang (socket)
Figure A-2. AMP Multilock Connector: Socket and Pin
Housings
Inserting Terminals into Housing
NOTE
See
Figure
A-3. Cavity numbers are stamped into the sec-
ondary locks of both the socket and pin housings. Match the
wire color to the cavity number found on the wiring diagram.
1.
Hold the terminal so the catch faces the tang in the
chamber. Insert the terminal into its numbered cavity until
it snaps in place.
A-2 2009 XB Service: Appendix A Connector Repair
2
3
2
1
6
NOTES
Up and down can be determined by the position of the
release button, the button is the top of the connector.
On the pin side of the connector, tangs are positioned at
the bottom of each cavity, so the slot in the pin terminal
(on the side opposite the crimp tails) must face downward.
On the socket side, tangs are at the top of each cavity, so
the socket terminal slot (on the same side as the crimp
tails) must face upward.
2.
Gently tug on wire end to verify that the terminal is locked
in place.
3.
Rotate the hinged secondary lock inward until tabs fully
engage latches on both sides of connector.
sm00005
1
1
2
1
3
5
1. 3-place housing
2. 6-place housing
3. 10-place housing
Figure A-3. AMP Multilock Connector: Cavity Numbers on
Secondary Locks (Socket Housings Shown)
Preparing Wire Leads for Crimping
1.
Strip 5/32 in. (4.0 mm) of insulation from the wire lead.
– AMP
2
3
– AMP
2
3
4
5
6
6
7
8
9
10