Cleaning

not install under overhead plumbing, sprinkler system valves, or in areas that
are susceptible to flooding
Lighting: Sufficient lighting is required for testing and maintenance
Lightning Protection/Grounding: The system must be properly grounded to
protect from lightning damage The following UL conditions must be met to
ensure proper grounding (For grounding instructions, see page 3-5 )
l
l
l
l
l
Cleaning
l
l - 4
Supplemental and independent equipment grounding conductors are to be
installed between the system and the wiring system ground
One of the equipment grounding conductors must be a conductor that is as
large or larger than the ungrounded branch-circuit supply conductors The
equipment grounding conductor is to be installed as part of the circuit that
supplies the system and is to be connected to ground at the service
equipment Bare, covered or insulated grounding conductors are
acceptable Lndividually covered or insulated grounding conductors should
have a continuous outer finish that is either green or green with one or
more yellow stripes The equipment grounding conductor should be
connected to ground at the service equipment.
The other equipment grounding conductor shall comply with the general
rules for grounding contained in
but its connection to ground shall not depend on the cord and
plug of the system
The attachment-plug receptacles of the same type as that used by the
systems that are in the vicinity of the DBS 824 are all to be of a grounding
type, and the equipment grounding conductors serving these receptacles
are to be connected to earth ground at the service equipment
A marking adjacent to the telecommunications jacks must instruct the user
to connect a supplementary equipment grounding conductor before any
telecommunication lines are connected to the product or system
slightly
Use a
damp cloth to clean the phones The phones should never be
cleaned with benzene, paint thinner, or other solvents
DBS 824-10-300
Article 250
the National Electric Code,
of
Requirements
issued 3/l /95