Remote Maintenance

(CPC-S and CPC-M)
Description
The DBS 824 can be programmed from a remote terminal or from a remote
PC by connecting via modems to the Maintenance port on the Serial Interface
Unit (SIU) The Remote Programming Mode may also be used locally by
directly connecting to the Maintenance Port

Remote Programming Mode

(CPC-S and CPC-M)
Description
Remote Programming Mode uses a modem connected to a "dumb" terminal
or a PC terminal program to access a modem connected to the DBS 824
Maintenance serial port. Local programming bypasses the modems and
connects directly from the PC or terminal to the Maintenance serial port
When programming from a terminal connected to the RS-232C
(Maintenance) port either directly or via a modem, perform the following
steps
1
2
3
4
5
issue Date 3/l/95
Make certain that any cables and modems are configured and connected
as outlined in Section 300
Enter your terminal communications program and make sure your PC's
data communications settings match those of the DBS 824
If connecting remotely using modems, dial up the DBS 824 Maintenance
port modem following the procedures for your terminal package Once
connected, if the Bus Monitor is active, Bus monitor information may
display
Set the DBS 824 to the terminal communications mode by entering or
have someone on site enter the following code at an extension or
attendant position
After the DBS 824 displays the DBS Remote Programming Banner
Screen, type P and then press Enter