Co Delayed Night 1 Ring Assignments - Panasonic DBS 824 Manual

Hide thumbs Also See for DBS 824:
Table of Contents

Advertisement

CO Delayed Night 1 Ring Assignments

CO Delayed Night 1 Ring Assignments
Software Versi'on CPC-S and CPC-M, Version 1 0 and higher
Address FF4 6## (ExtPort)# (Trunk)# (0 or l)#
Description
This program assigns delayed ringing to extensions for unanswered calls on
specific trunks during the "Night 1' mode Delayed ringing works like an
automatic transfer -- if an incoming trunk call is unanswered at one extension
after a certain period of time, the system will send the call to ring at another
extension (the first extension will stop ringing)
The original extension or hunt group that receives an incoming trunk call
during "Night 1" mode is set in the CO Night 1 Ring Assignments address
(FF4 2# ExtPort/HunGrp# Trunks) The period of time that passes before
the system transfers the unanswered call, is set in the CO Delayed Ring Timer
address (FFl 3# 22#)
Programming
Related Programming
Delayed Ring FFl 2# l# 21# (0 or l)#
CO Delayed Ring Timer FFl 3# 22# (0-15)##
Automatic Night 1 Mode Start Time FFl 3# l# HHMM#
CO Night 1 Ring Assignments FF4 2# (ExtPort)# (Trunk)# (0 or l)#
Notes
Attendant Interactions If the first attendant is assigned delayed ringing, the
Attendant Overflow feature will be disabled Also, if the Delayed Ring
function is enabled and no extensions are assigned or capable of ringing
attendant
4-16
FF4 6# (I-17 or l-25)# (l-6 or l-8)# (0 or l)#
Extension Port
CPC-S l-16, 17
CPC-M l-24,25
Note: Use port 17 (CPC-S) or port 25 (CPC-M) to assign ringing to an
external paging or Universal Night Answer (UNA) device
Trunk Number
if the trunk call is
CPC-S l-6
unanswered elsewhere
CPC-M l-8
trunk call is unanswered
elsewhere
FF4
issued 3/l /95

Advertisement

Table of Contents
loading