External Paging - Panasonic DBS 824 Manual

Hide thumbs Also See for DBS 824:
Table of Contents

Advertisement

External Paging

External Paging
Guidelines
l
l
l
l
l
l
Non-Zoned Page instaiiation (CPC-M Only)
1
2
5-16
CPC-S does not provide any page relay controls Paging Audio output is
provided at the EPA connector for external pages It is recommended that
the EPA output be connected to a voice-activated amplifier to eliminate
background "white" noise
CPC-M provides a paging audio output (EPA), page zone relay terminals
(AZ, 21-24) and external page relay terminals (B2, C2 and M2) Since the
relays are not provided with the CPC-S card, external Zone Paging is only
available with the CPC-M Circuit Card
The maximum current for each zone paging terminal on the CN4
Connector Panel (Terminals AZ, 21-24) is 50 mA, the resistance of the
relay used for each zone paging terminal must be 2600 to 2800 Ohms
The paging amplifier relays and speakers are not provided with the DBS
824 They must be purchased separately
The EPA connector (CN5) is used to connect the paging amplifier The
output impedance of CN5 is 600 Ohms
B2 (Break 2), C2 (Common 2) and M2 (Make 2) may be used to activate a
non-zoned external Paging Installation Any page defined as external
activates these relay contacts
Connect the amplifier speaker output in series with the "C2" and "M2"
terminals on the CN4 Connector Panel as shown in Figure 5-14
Connect the CN5 "EPA' connector to the amplifier
DBS 824-l O-300