Configuring Phone Lines and Calling Routing Behavior
Interdigit Long Timer (Incomplete Entry Timer)
You can think of this timer as the "incomplete entry" timer. This timer measures the interval
between dialed digits. It applies as long as the dialed digits do not match any digit sequences
in the dial plan. Unless the user enters another digit within the specified number of seconds,
the entry is evaluated as incomplete, and the call is rejected. The default value is 10 seconds.
This section explains how to edit a timer as part of a dial plan.
Note
Alternatively, you can modify the Control Timer that controls the default
interdigit timers for all calls. See
Default Interdigit Values, " on page
Syntax for the Interdigit Long Timer
SYNTAX:
:s,
L
( dial plan )
s: The number of seconds; if no number is entered after
seconds applies.
Note that the timer sequence appears to the left of the initial parenthesis for the dial
plan.
Example for the Interdigit Long Timer
EXAMPLE:
L:15,
(9,8<:1408>[2-9]xxxxxx | 9,8,1[2-9]xxxxxxxxx | 9,8,011xx. | 9,8,xx.|[1-8]xx)
This dial plan allows the user to pause for up to 15 seconds between digits before the
L:15,
Interdigit Long Timer expires. This setting is especially helpful to users such as sales people,
who are reading the numbers from business cards and other printed materials while dialing.
Setting the Interdigit Long Timer for the System Dial Plan
Follow the procedure
"Editing the System Dial Plan, " on page
Interdigit Short Timer (Complete Entry Timer)
You can think of this timer as the "complete entry" timer. This timer measures the interval
between dialed digits. It applies when the dialed digits match at least one digit sequence in the
dial plan. Unless the user enters another digit within the specified number of seconds, the entry
is evaluated. If it is valid, the call proceeds. If it is invalid, the call is rejected. The default value is
3 seconds.
This section explains how to edit a timer as part of a dial plan.
Note
Alternatively, you can modify the Control Timer that controls the default
interdigit timers for all calls. See
Default Interdigit Values, " on page
Linksys Voice System Administration Guide
Configuring Dial Plans
"Editing the Control Timers for the
62.
, the default timer of 5
L:
57.
"Editing the Control Timers for the
62.
61

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Spa400Spa9x2

Table of Contents