Linksys SPA9000 Administration Manual page 183

Voice system ip telephony system pstn voip gateway with integrated voice mail server ip phones
Hide thumbs Also See for SPA9000:
Table of Contents

Advertisement

Interdigit Long Timer
Interdigit Short Timer
CPC Delay
CPC Duration
Voice tab > Regional page
Vertical Service Activation Codes section
Vertical Service Activation Codes are automatically appended to the
Note
dial-plan. There is no need to include them in dial-plan, although no
harm is done if they are included.
Call Return Code
Call Redial Code
Blind Transfer Code
Call Back Act Code
Linksys Voice System Administration Guide
Long timeout between entering digits when dialing. The interdigit timer
values are used as defaults when dialing. The Interdigit_Long_Timer is
used after any one digit, if all valid matching sequences in the dial plan
are incomplete as dialed. Range: 0–64 seconds.
Default: 10
Short timeout between entering digits when dialing. The
Interdigit_Short_Timer is used after any one digit, if at least one
matching sequence is complete as dialed, but more dialed digits would
match other as yet incomplete sequences. Range: 0–64 seconds.
Default: 3
Delay in seconds after caller hangs up when the SPA9000 starts
removing the tip-and-ring voltage to the attached equipment of the
called party. Range: 0–255 seconds. SPA9000 has had polarity reversal
feature since release 1.0 which can be applied to both the caller and the
callee end. This feature is generally used for answer supervision on the
caller side to signal to the attached equipment when the call has been
connected (remote end has answered) or disconnected (remote end has
hung up). This feature should be disabled for the called party (in other
words, by using the same polarity for connected and idle state) and the
CPC feature should be used instead.
Without CPC enabled, reorder tone is played after a configurable delay.
If CPC is enabled, dial tone is played when tip-to-ring voltage is restored
Resolution is 1 second.
Default: 2
Duration in seconds for which the tip-to-ring voltage is removed after
the caller hangs up. After that, tip-to-ring voltage is restored and dial
tone applies if the attached equipment is still off-hook. CPC is disabled if
this value is set to 0. Range: 0 to 1.000 second. Resolution is 0.001
second.
Default: 0 (CPC disabled)
This code calls the last caller.
Default: *69
Redials the last number called.
Default: *07
Begins a blind transfer of the current call to the extension specified after
the activation code.
Default: *98
Starts a callback when the last outbound call is not busy.
Default: *66
Voice tab
181

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Spa400Spa9x2

Table of Contents