Configuring Phone Lines and Calling Routing Behavior
Terminating Event
A timeout occurs.
The user presses the # key or the dial
softkey on the phone display.
Editing the System Dial Plan
Follow this procedure to edit the system dial plan, which will be auto-provisioned to the first
extension of each phone.
1. Connect to the SPA9000 administration web server, and choose Admin access with
Advanced settings. (See
page
24.)
2. Click Voice tab > SIP.
3. Scroll down to the PBX Phone Parameters section.
4. Enter the digit sequences in the Dial Plan field. For more information and examples, see
"Digit Sequences and Functions, " on page
Linksys Voice System Administration Guide
Processing
The number is rejected if the dialed
digits are not matched to a digit
sequence in the dial plan within the time
specified by the applicable interdigit
timer.
•
The Interdigit Long Timer applies
when the dialed digits do not match
any digit sequence in the dial plan.
The default value is 10 seconds.
•
The Interdigit Short Timer applies
when the dialed digits match one or
more candidate sequences in the dial
plan. The default value is 3 seconds.
For more information, see
Timers for the Dial Plan, " on page
•
If the sequence is complete and is
allowed by the dial plan, the number
is accepted and is transmitted
according to the dial plan.
•
If the sequence is incomplete or is
blocked by the dial plan, the number
is rejected.
"Connecting to the SPA9000 Administration Web Server, " on
SPA9000 Voice > SIP: PBX Phone Parameters
53.
Configuring Dial Plans
"Setting the
59.